calculadora de ingeniería

Voltage Coefficient (VCR) Error Calculator

VinR1(V)VoutR20 VR0VRR(V)dR/R

Cómo leer el diagrama. The top resistor changes value as the voltage across it rises, so the ratio at 20 kV is not the ratio you measured on the bench. The curve is that drift and dR/R is the error the calculator returns.

A thick film resistor is not the same value at 20 kV as on a bench meter. VCR is quoted in ppm per volt; this turns it into the resistance change and the divider error it causes.

Ingresos

Resultados

R1 change
-
Ratio at 0 V
-
Ratio at working V
-
Error de proporción
-
Output at working V
-

La fórmula

ΔR/R = VCR × V / 1,000,000. Divider ratio = (R1 + R2) / R2; recalculate it with the shifted R1 to get the error.

Lo que la calculadora no incluye

Eligiendo las partes

Where the ratio matters, specify VCR explicitly: the gama de películas gruesas planas is quoted for precision divider use, tolerance from 0.2%. For matched pairs, send the ratio and the voltage.

Envíe los valores calculados y el arancel: Solicitar presupuesto técnico, respuesta en 6 horas.